Aquasant Products

Aquasant Messtechnik AG was founded in 1982, with the objective of offering the highest quality measuring instruments to the chemical industry.

Increasing needs of instrument installations in the fields of automation and safety have resulted in a specific range of electro-optical and impedance measurement, monitoring and control devices.

Achieving integral problem solutions led in 1986 to the founding of our second company, Treina Electronics AG. New technology instruments have been developed because of difficult measuring problems with new fluids, foams and powders. Two unique applications of Aquasant MT impedance measurement technology are Interface Detection and Foam Detection.

TSS 80 Pipe Probe

Automatic inline batch phase separation of non-mixable liquids and emulsions in Glass lined Reactors & Vessels in the Pharma Industry is now easily achieved using Aquasant’s In-Line Full bore interface detector mounted directly in the pipeline or on the outlet of the Vessel / Reactor.

2 Download PDF

STM Bar Probe

To Detect the Interfacial layer measurement of 2 non-mixable liquids, as result of an extraction or as occurring after a chemical process, is still today very problematic. Heavy contaminations, small differences of Densities, Dielectric Constants and Conductivities and/or emulsion layers are all issues that make Interface Detection one of the most difficult automated processes.

However, this now a thing of the past, if you are using the full electronic interface detection system of Aquasant Messtechnik AG with its norm signal of the high-resolution impedance measurement. With interface detection pipe probes of different diameters, it is possible to measure the interface directly at the reactor or separation vessel output line. The self-controlled measuring system and control unit do assure a secure and fully automatic separation.

For continuous separators, interface bar probes are used. The interface layer level is measured without any mechanical moving parts and the analogue 0/4 – 20 mA signal goes to the regulator or to the central process system.

2 Download PDF

Mipromex MIQ 8130 Measuring Unit

To Detect the Interfacial layer measurement of 2 non-mixable liquids, as result of an extraction or as occurring after a chemical process, is still today very problematic. Heavy contaminations, small differences of Densities, Dielectric Constants and Conductivities and/or emulsion layers are all issues that make Interface Detection one of the most difficult automated processes.

However, this now a thing of the past, if you are using the full electronic interface detection system of Aquasant Messtechnik AG with its norm signal of the high-resolution impedance measurement. With interface detection pipe probes of different diameters, it is possible to measure the interface directly at the reactor or separation vessel output line. The self-controlled measuring system and control unit do assure a secure and fully automatic separation.

For continuous separators, interface bar probes are used. The interface layer level is measured without any mechanical moving parts and the analogue 0/4 – 20 mA signal goes to the regulator or to the central process system.

2 Download PDF